Lg DLGX8001V Manuale Utente Pagina 27

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 26
27
ENGLISH
INSTALLATION INSTRUCTIONS
Connecting electric dryer(cont.)
USA only
w
WARNING










Three-Wire connection for electric dryers:
Power cord
A 3-wire connection is NOT permitted on new construction after
January 1, 1996.
• A UL-listed strain relief is required.
1. Remove the terminal block access cover on the upper back of
the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed, 
 conductor power cord through the
strain relief.
Use a 
 conductor and closed loop or forked
terminals with upturned ends.
2. Attach the two hot leads of the power cord to the outer
terminal block screws. Attach the neutral wire to the center
terminal block screw. Connect the external ground (if required
by local codes) to the green ground screw. 
. Reinstall the terminal block access cover.
UL-Listed
Strain Relief
UL-Listed
3-Wire Power
Cord
Terminal
Block
Ground
Screw
Neutral
(White)
Hot
(Black)
External
Ground Wire
Hot
(Red)
Vedere la pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 99 100

Commenti su questo manuale

Nessun commento