5.2 Regulation for LPG
Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one,
following the instructions indicated in the reference charts, with
respect to the type of gas to use. The screwing torque of the nozzle
should never exceed 3 Nm. Reposition support B so that nozzle C
is covered perfectly.
Move the Venturi tube D to regulate the air flow until distance "X" is
reached indicated in the chart in paragraph "5.4 Regulation of
primary air” and then secure the tube by means of screw A. After
the regulations have been carried out, restore the seals with sealing
wax or equivalent material.
(*) By-pass value for valveless appliances.
Burner LPG - G30/G31 28/37 mbar
Rated
heating
capacity
(kW)
Nozzl
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Rapid (4)
Ultra rapid (5)
1.05
1.65
2.55
3.1
3.9
48
62
76
85
95
380
380
650
750
1600
76
120
185
225
283
75
118
182
222
279
30
30
37
43
65
33(*)
33(*)
40(*)
45(*)