INSTALLATION MANUAL
Original instruction
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards
by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ČEŠTINA
ΕΛΛΗΝΙΚΆ
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Vedere la pagina 0
1 2 3 4 5 6 ... 30 31

Sommario

Pagina 1 - CONDITIONER

P/NO : MFL67798017INSTALLATION MANUALOriginal instruction[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Servi

Pagina 2 - IMPORTANT SAFETY INSTRUC

10ENGLISH• Fix the unit tightly with bolts as shown below so that unit will not falldown due to earthquake or gust.• Use the H-beam support as a base

Pagina 3

11ENGLISHFlaring work- Carry out flaring work using flaring tool as shown below.Firmly hold copper tube in a bar(or die) as indicated dimension in the

Pagina 4

12ENGLISH1 Always use the nitrogen.(not use oxygen, carbon dioxide, anda Chevron gas): Please use the following nitrogen pressure0.02MPa Oxygen – Pro

Pagina 5 - TABLE OF CONTENTS

13ENGLISH- Pipe connections can be done on the front side or on the side accord-ing to the installation environments.- Be sure to let 0.2kgf/cm2Nitrog

Pagina 6 - INSTALLATION PROCESS

14ENGLISHTotal pipe length = A+B+C+D+a+b+c+d+e ≤ 300mLLongest pipe length Equivalent pipe length(*)A+B+C+D+e ≤ 150m A+B+C+D+e ≤ 175mlLongest pipe leng

Pagina 7 - Air inlet grille

15ENGLISH• * : Assume equivalent piping length of Y branch to be 0.5m, thatof header to be 1m, calculation purpose• Indoor Unit should be installed at

Pagina 8 - 500 or less

16ENGLISHIndoor Unit ConnectionIndoor Unit connecting pipe from branch (a,b,c,d,e,f)Indoor Unit capacity[kW(Btu/h)]Liquid pipe[mm(inch)]Gas pipe [mm(i

Pagina 9 - Secure minimum intake area

17ENGLISH1st1st1stMain pipeDistribution2nd2nd3rd3ndMain pipeDistribution1st3rd3rd main pipe distribution2ndHorizontal Distribution• When the number of

Pagina 10 - INSTALLATION

18ENGLISH• Joints between branch and pipe should be sealed with the tape in-cluded in each kit.• Any cap pipe should be insulated using the insulator

Pagina 11 - R=0.4~0.8

19ENGLISHNOTE!If the ambient temperature differs between the time when pressure isapplied and when the pressure drop is checked, apply the followingco

Pagina 12 - Nitrogen substitution method

2ENGLISHTIPS FOR SAVING ENERGYHere are some tips that will help you minimize the power consumptionwhen you use the air conditioner. You can use your a

Pagina 13 - INDOOR AND OUTDOOR UNIT

20ENGLISHBe sure to give insulation work to refrigerant piping by covering liquidpipe and gas pipe separately with enough thickness heat-resistant pol

Pagina 14 - Y branch method

21ENGLISH2-Core Shield CableMulti-Core CableRemotecontrolRemotecontrolRemotecontrolRemotecontrolIndoorUnitOutdoor UnitOutdoor UnitIndoorUnitIndoorUnit

Pagina 15

22ENGLISHNOTE!• The figures are based on assumed length of parallel cabling upto 100m. For length in excess of 100m the figures will have tobe recalcu

Pagina 16 - Refrigerant charging

23ENGLISHMasterOutdoor UnitSODU. B SODU. A IDU. B IDU. A CEN. B CEN. A DRY1 DRY2 GND 12V34 34 34[Heat Pump]Between Indoor and Master Outdoor uni

Pagina 17 - Pinched pipe

24ENGLISH- About more information of IO Module, please refer to IO Modulemanual.CAUTIONBe sure to turn off outdoor unit power before installation.!++※

Pagina 18 - Y branch pipe

25ENGLISHExample) Group number setting 1stnumber indicate the group number2nd number point out indoor unit numberSODU.B SODU.A IDU.B IDU.A CEN.B CEN.A

Pagina 19 - Gas side

26ENGLISHCAUTION• Request installer to set the function during installation. • If ODU RPM changes, cooling capacity may go down.!Master unit PCB DIP s

Pagina 20 - Power lines

27ENGLISHError No. of CompressorError No.Error No. of UnitRepeatDisplay Title Cause of ErrorIndoor unit related error0 1 -Air temperature sensor of in

Pagina 21 - Side panel

28ENGLISHDisplay Title Cause of Error5 0 1Omitting connection of R, S, T power of Outdoor Unit Omitting connection of outdoor unit5 1 1Excessive capac

Pagina 22 - 50Hz 380~415V 220~240V

29ENGLISHCalculate minimum room capacityCalculate room capacity by regarding a portion as one room or thesmaller room.- With partition and with openin

Pagina 23 - Outdoor Unit

3ENGLISH• Do not install the product on a defective in-stallation stand.- It may cause injury, accident, or damage tothe product.• Use a vacuum pump o

Pagina 24 - Automatic Addressing

CAUTION• Air conditioners should not be installed in areas wherecorrosive gases, such as acid or alkaline gas, are produced.• Do not install the produ

Pagina 26

4ENGLISHunit, an explosion may result.• Use power cables of sufficient current carryingcapacity and rating. - Cables that are too small may leak, ge

Pagina 27 - Error No. of Unit

5ENGLISH• Auto-addressing should be done in condition of con-necting the power of all indoor and outdoour units.Auto-addressing should also be done in

Pagina 28

6ENGLISHThe foundation must be level evenOutdoor unit foundation workAvoid short circuits and ensure sufficient space is allowed for serviceInstallatio

Pagina 29 - Smallest

7ENGLISHAir inlet grille700[Unit : mm]Turn the air outlet side toward thebuilding's wall, fence or windbreak screen.WARNINGFix the outdoor unit f

Pagina 30 - Product information

8ENGLISHIn case of obstacles on the discharge side1. Stand alone installationa500 or lessmore1,000 ora2. Collective installation1,000 or more100 ormor

Pagina 31

9ENGLISHSeasonal wind and cautions in winter• Sufficient measures are required in a snow area or severe cold areain winter so that product can be oper