INSTALLATION MANUAL
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
Ɠ
This product contains Fluorinated Greenhouse Gases. (R410A)
[
Representative
]
LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[
Manufacturer
]
LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
Single Inverter Outdoor Unit
Original instruction
ENGLISH
ITALIANO ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
1,MFL68907802(영) 17. 7. 21. 영영 7:18 Page 1
Vedere la pagina 0
1 2 3 4 5 6 ... 26 27

Sommario

Pagina 1 - CONDITIONER

P/NO : MFL68907802INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installatio

Pagina 2 - TIPS FOR SAVING ENERGY

10INSTALLATION OF INDOOR, OUTDOOR UNITENGLISH- If an awning is built over the unit to prevent directsunlight or rain exposure, make sure that heatradi

Pagina 3 - IMPORTANT SAFETY INSTRUCTIONS

CONNECTING PIPESINSTALLATION OF INDOOR, OUTDOOR UNIT11ENGLISHMain cause of gas leakage is defect in flaring work. Carry out correct flaring work in th

Pagina 4

12CONNECTING PIPESENGLISHConnection of piping -Outdoor- Align the center of the piping and sufficiently tighten the flare nut by hand.- Finally, tight

Pagina 5

CONNECTING PIPES13ENGLISHForming the pipingForm the piping by wrapping the connectingportion of the indoor unit with insulation mate-rial and secure i

Pagina 6

14WIRING CONNECTIONENGLISHConnecting Cables between Indoor Unit and Outdoor Unit- Connect the wires to the terminals on the control board individually

Pagina 7

WIRING CONNECTION15ENGLISHCAUTION!The power cord connected to the outdoor unit should comply to IEC 60245 or HD 22.4 S4(This equipment shall be provid

Pagina 8 - TABLE OF CONTENTS

16WIRING CONNECTIONENGLISHConnecting the cable to Outdoor UnitRemove the side panel for wiring connection.Use the cord clamp to fix the cord.Earthing

Pagina 9 - INSTALLATION

LEAKAGE TEST AND EVACUATION17ENGLISHAir and moisture remaining in the refrigerant system have undesirable effects as indicated below.- Pressure in the

Pagina 10 - INSTALLATION OF OUTDOOR UNIT

18LEAKAGE TEST AND EVACUATIONENGLISHEvacuation- Connect the charge hose end described in thepreceding steps to the vacuum pump to evac-uate the tubing

Pagina 11 - CONNECTING PIPES

TEST RUNNING19ENGLISH1 Precautions In Test Running- The initial power supply must provide at least 90% of the rated voltage.Otherwise, the air conditi

Pagina 12 - Connection of piping

2TIPS FOR SAVING ENERGYENGLISH• Excessive cooling may be harmful to your health and may consume more electricity.• Block sunlight with blinds or cur

Pagina 13 - Forming the piping

20TEST RUNNINGENGLISHHAND OVERTeach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperatur

Pagina 14 - WIRING CONNECTION

INSTALLATION PI48521ENGLISHFix the PI485 PCB as shown in below images.For detailed installation method refer to PI485 Installation Manual. UU18WUU24W

Pagina 15 - 3 Phase(Ø)

22FUNCTIONENGLISHDip S/W Setting (UU18W/UU24W/UU30W)If you set the Dip Switch when power is on, the change in setting is notapplicable. The changing s

Pagina 16

FUNCTION23ENGLISHForced Cooling OperationAdding the refrigerant in winter.Setting Procedure1 Set the Dip Switch as follow after shutting the power sou

Pagina 17 - LEAKAGE TEST AND EVACUATION

24FUNCTIONENGLISHSaving Power ConsumptionSaving Power Consumption operation is thefunction which enables efficient operation bylowering the maximum po

Pagina 18 - Evacuation

FUNCTION25ENGLISHNight Quiet Mode with Mode Lock.Mode Lock (Cooling) + Night Quiet Mode(step 1)Mode Lock (Cooling) + Night Quiet Mode (step 2)CAUTION•

Pagina 19 - TEST RUNNING

26ENGLISHINSTALLATION GUIDE AT THE SEASIDEIf the outdoor unit is to be installed close tothe seaside, direct exposure to the sea windshould be avoided

Pagina 20

1,MFL68907802(영) 17. 7. 21. 영영 7:18 Page 500

Pagina 21 - INSTALLATION PI485

IMPORTANT SAFETY INSTRUCTIONS3ENGLISHIMPORTANT SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.Always comply with the following pr

Pagina 22 - FUNCTION

4IMPORTANT SAFETY INSTRUCTIONSENGLISH• Do not modify or extend the power cable. If power cable is dam-aged or has deteriorated, then it must be replac

Pagina 23 - Forced Cooling Operation

IMPORTANT SAFETY INSTRUCTIONS5ENGLISH• Be sure to use only those parts which are listed in the svc partslist. Never attempt to modify the equipment

Pagina 24 - Night Quiet Mode

6IMPORTANT SAFETY INSTRUCTIONSENGLISHCAUTIONInstallation• Two or more people must lift and transport the product. Avoidpersonal injury. • Do not insta

Pagina 25 - Mode Lock

IMPORTANT SAFETY INSTRUCTIONS7ENGLISH• Do not insert hands or other objects through the air inlet or outletwhile the product is operating. There are

Pagina 26 - AT THE SEASIDE

8TABLE OF CONTENTSENGLISH2 TIPS FOR SAVING ENER-GY9 INSTALLATION10 INSTALLATION OF OUT-DOOR UNIT11 CONNECTING PIPES11 Preparation of Piping12 Connecti

Pagina 27

INSTALLATION9ENGLISHmore than30cmmore than30cmFigure FigureNameScrew driverElectric drillMeasuring tape, KnifeHole core drillSpannerTorque wrenchMulti

Commenti su questo manuale

Nessun commento