www.lg.com
2 Points Dry Contact (For Setback)
Please read this usage/installation manual completely before installing the product.
Usage/Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
INSTALLATION MANUAL
AIR
CONDITIONER
P/NO : MFL69265515
ENGLISH
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - CONDITIONER

www.lg.com2 Points Dry Contact (For Setback)Please read this usage/installation manual completely before installing the product.Usage/Installation wor

Pagina 2 - TABLE OF CONTENTS

Setting and using method10 Dry Contact for setback2. Setting of Contact Signal Inputn For no power contact point signal inputn For power contact point

Pagina 3 - Safety Precautions

Setting and using methodInstallation Manual 11ENGLISH3. Setting the desired temperaturen When setting the desired temperature of the Dry Contact ForS

Pagina 4 - Standardized

Setting and using method12 Dry Contact for setback4. Control mode settingn Use the CONTROL_MODE_SW to set the control mode youwant from 0~E. n Descrip

Pagina 5 - Installation Manual 5

Setting and using methodInstallation Manual 13ENGLISH2) General mode Input A Input B

Pagina 6 - Part Description

Setting and using method14 Dry Contact for setback3) Fan level setting mode4) Power save modeÚ When the indoor unit is operating with a Dry Contact Fo

Pagina 7 - Installation

Setting and using methodInstallation Manual 15ENGLISH5) Compressor stop modeÚ Compressor stop mode: The compressor is stopped during cool/heat operat

Pagina 8 - 8 Dry Contact for setback

Setting and using method16 Dry Contact for setbackÚ When Indoor unit is operating as Cooling Thermal On Mode Relay output is closed.5. Indoor unit mon

Pagina 9

2 Dry Contact for setbackDry Contact for setback Unit Installation ManualTABLE OF CONTENTS n Safety Precautions...

Pagina 10 - Setting and using method

Safety PrecautionsInstallation Manual 3ENGLISHn InstallationServiceCenterServiceCenterTo prevent injury to the user or other people and property dama

Pagina 11 - SETTING_SW

StandardizedproductSafety Precautions4 Dry Contact for setbackDo not install the productin the place where rain canget to the product.• Cause product

Pagina 12 - CONTROL_MODE_SW

ServiceCenterSTOPSafety PrecautionsInstallation Manual 5ENGLISHDo notspill water inside ofthe product.• Cause electric shock orbreakdown.If the prod

Pagina 13

6 Dry Contact for setbackPart DescriptionNOTUSBeCN_OUTCHANGEOVER_SWVOLTNONVOLTTEMPSETTING1258973611104Front Case Rear CaseMetal Case (Front) Metal Cas

Pagina 14 - 14 Dry Contact for setback

Part DescriptionInstallation Manual 7ENGLISHInstallation1) Loosen and remove two screws that secures the product. 2) Remove the front metal case by p

Pagina 15 - Installation Manual 15

Part Description8 Dry Contact for setback6) Remove knock out shapes on the rear case (2-sided) according to the connector’s size and direc-tion.7) Con

Pagina 16 - 5. Indoor unit monitoring

Setting and using methodInstallation Manual 9ENGLISHSetting and using method1. Power supply and indoor unit connectionYou must press the RESET switch

Commenti su questo manuale